N2XS2Y Cable

N2XS2Y Cable

  • N2XS2Y Cable is a single-core medium-voltage power cable with a stranded copper conductor, XLPE insulation, copper wire screen and polyethylene outer sheath.
  • The designation is used for fixed medium-voltage distribution where a PE-sheathed cable is preferred for underground, water-exposed, outdoor, duct and demanding utility routes. Common project voltage classes include 6/10 kV, 8.7/15 kV, 12/20 kV and 18/30 kV under IEC and VDE-oriented specifications.
  • RS supplies N2XS2Y as a project cable configuration where conductor size, copper screen section, voltage class, PE sheath requirement, test documents and export packing are matched to the cable schedule and destination market.
Email UsGet Free Quote

Product Introduction

CONSTRUCTION

Conductor:

Class 2 stranded copper conductor, round compacted where specified

Insulation:

XLPE insulation with inner and outer semiconductive screens

Metallic Screen:

Copper wire screen with counter helix; screen section selected by fault-current requirement

Outer Sheath:

Polyethylene outer sheath, commonly black; MDPE or HDPE direction follows the project specification

CHARACTERISTICS

Voltage Classes:

6/10 kV, 8.7/15 kV, 12/20 kV and 18/30 kV project classes

Conductor Temperature:

XLPE medium-voltage designs commonly use 90°C maximum conductor temperature in normal service

Installation:

Fixed installation indoors, outdoors, in ducts and in ground routes with suitable mechanical and thermal design

STANDARDS:

Common references include IEC 60502-2, VDE 0276-620, IEC 60228 and IEC 60332-1-2. Standard reference is not a certification claim.

N2XS2Y Cable Technical Data

Recommended Reference Data: N2XS2Y is normally a single-core screened medium-voltage cable. The size format below is conductor cross-section / copper screen cross-section in mm2.

Ampacity values are reference values for one single-core circuit in air at 30°C with load factor 1.0 and three-cable bunching, or in ground at 20°C with load factor 0.7 and three-cable bunching. Final project current rating depends on soil thermal resistivity, burial depth, spacing, grouping, sheath bonding, route temperature and local calculation method. Final RS manufacturing dimensions and test values follow the approved quotation datasheet.

N2XS2Y 6/10 kV Recommended Data

Voltage class Cable size Conductor resistance at 20 C (ohm/km) Insulation thickness (mm) PE sheath thickness (mm) Approx. OD (mm) Approx. weight (kg/km) Ampacity in air 30 C (A) Ampacity in ground 20 C (A)
6/10 kV 1 x 35/16 0.524 3.4 2.5 24 900 197 187
6/10 kV 1 x 50/16 0.387 3.4 2.5 25 950 236 220
6/10 kV 1 x 70/16 0.268 3.4 2.5 27 1200 294 268
6/10 kV 1 x 95/16 0.193 3.4 2.5 28 1450 358 320
6/10 kV 1 x 120/16 0.153 3.4 2.5 30 1700 413 363
6/10 kV 1 x 150/25 0.124 3.4 2.5 31 2050 470 409
6/10 kV 1 x 185/25 0.0991 3.4 2.5 33 2400 535 456
6/10 kV 1 x 240/25 0.0754 3.4 2.5 35 2950 631 526
6/10 kV 1 x 400/35 0.0470 3.4 2.5 41 4500 827 662

N2XS2Y 12/20 kV Recommended Data

Voltage class Cable size Conductor resistance at 20 C (ohm/km) Insulation thickness (mm) PE sheath thickness (mm) Approx. OD (mm) Approx. weight (kg/km) Ampacity in air 30 C (A) Ampacity in ground 20 C (A)
12/20 kV 1 x 35/16 0.524 5.5 2.5 28 970 200 189
12/20 kV 1 x 50/16 0.387 5.5 2.5 29 1150 239 222
12/20 kV 1 x 70/16 0.268 5.5 2.5 31 1350 297 271
12/20 kV 1 x 95/16 0.193 5.5 2.5 32 1650 361 323
12/20 kV 1 x 120/16 0.153 5.5 2.5 34 1900 416 367
12/20 kV 1 x 150/25 0.124 5.5 2.5 35 2250 470 409
12/20 kV 1 x 185/25 0.0991 5.5 2.5 37 2600 538 461
12/20 kV 1 x 240/25 0.0754 5.5 2.5 40 3200 634 532
12/20 kV 1 x 400/35 0.0470 5.5 2.5 45 4750 829 671

N2XS2Y 18/30 kV Recommended Data

Voltage class Cable size Conductor resistance at 20 C (ohm/km) Insulation thickness (mm) PE sheath thickness (mm) Approx. OD (mm) Approx. weight (kg/km) Ampacity in air 30 C (A) Ampacity in ground 20 C (A)
18/30 kV 1 x 50/16 0.387 8.0 2.5 34 1350 241 225
18/30 kV 1 x 70/16 0.268 8.0 2.5 36 1600 299 274
18/30 kV 1 x 95/16 0.193 8.0 2.5 37 1900 363 327
18/30 kV 1 x 120/16 0.153 8.0 2.5 39 2150 418 371
18/30 kV 1 x 150/25 0.124 8.0 2.5 40 2550 472 414
18/30 kV 1 x 185/25 0.0991 8.0 2.5 42 2900 539 466
18/30 kV 1 x 240/25 0.0754 8.0 2.5 44 3500 635 539

N2XS2Y Cable Construction

N2XS2Y is built around a stranded copper conductor with an extruded conductor screen, XLPE insulation and an insulation screen applied as part of the medium-voltage insulation system. A copper wire screen and counter helix provide the metallic screen path, followed by a polyethylene outer sheath.

The single-core construction is important. Current rating, screen bonding, induced sheath voltage, bending radius and termination design are evaluated differently from three-core MV cable. Where a tender requires a three-core screened cable, N2XSEY or another three-core designation may be the better match.

The copper screen section, commonly shown as the second number in a size such as 1 x 240/25 mm2, is selected according to earth-fault current and protection design. It is not decorative and must match the fault-current requirement of the system.

Applications for N2XS2Y Medium Voltage Cable

N2XS2Y cable is used in medium-voltage distribution networks where a screened single-core cable with PE sheath is accepted by the project specification. Common routes include transformer stations, switching stations, power plants, industrial feeders, renewable-energy collection networks and utility distribution circuits.

The cable can be installed indoors, outdoors, in ducts, in water and in ground routes when the installation design accounts for mechanical protection, pulling tension, bending radius, route temperature and current rating. The PE sheath supports stronger mechanical and moisture-resistance positioning than a conventional PVC sheath.

The PE sheath is not normally treated as a flame-retardant sheath under flame-test definitions used for PVC-sheathed cable. For tunnels, public buildings or routes requiring flame-retardant or low-smoke halogen-free performance, another MV cable design may be required.

N2XS2Y vs N2XSY, NA2XS2Y and N2XS(F)2Y

N2XS2Y and N2XSY share copper conductor, XLPE insulation and screened single-core MV cable logic, but the outer sheath differs. N2XSY uses PVC sheath; N2XS2Y uses PE sheath for routes where mechanical durability, water exposure or underground service is a stronger requirement.

NA2XS2Y is the aluminium-conductor companion to N2XS2Y. It can reduce conductor cost and weight, but conductor size, resistance, termination design and short-circuit performance are different from copper N2XS2Y.

N2XS(F)2Y adds a longitudinal water-blocking construction detail. It should not be treated as identical to standard N2XS2Y unless the project specification requires the `(F)` water-blocking layer and RS confirms that construction.

Model Main distinction Typical page role
N2XSY Copper conductor with PVC sheath PVC-sheath comparison
N2XS2Y Copper conductor with PE sheath This page
NA2XS2Y Aluminium conductor with PE sheath Next companion page
N2XS(F)2Y Copper conductor with PE sheath and longitudinal water blocking Separate water-blocked variant

Testing, Documents and Export Packing

N2XS2Y production documentation can include the approved datasheet, conductor resistance checks, voltage test records, partial-discharge test records, dimensional inspection, drum schedule, packing list and product photos. Type tests, flame-test evidence or third-party inspection are added only when required by the project and available for the exact construction.

Export packing is normally planned by cable weight, drum length, maximum drum diameter, route handling and container loading. Medium-voltage single-core cable can become heavy at large cross-sections, so drum length is part of the technical and logistics review, not only a shipping preference.

For quotation, RS needs the model designation, voltage class, conductor size, copper screen section, installation route, standard, quantity, preferred drum length, destination country and required documents. The information is used to confirm the cable configuration and issue a project-specific offer.

    Get Free Product Inquiry

    Our professional sales team will provide you with the best quotation and solution within 24 hours.

    Home WhatsApp Email Get Price