N2XY Cable

N2XY Cable

  • Voltage Rating Uo/U: 0.6/1 kV
  • Conductor Temperature: Maximum conductor temperature: 90°C under normal operation
  • Installation: Fixed installation in cable trays, ducts, conduits, buildings and protected outdoor or underground routes
  • STANDARDS: DIN VDE 0276-603 / HD 603, IEC 60502-1 and IEC 60228
Email UsGet Free Quote

Product Introduction

Description of N2XY Cable:

N2XY Cable is a 0.6/1 kV copper power cable with XLPE insulation and a PVC outer sheath. It is designed for fixed low-voltage power distribution in industrial plants, commercial buildings, infrastructure, utility systems, cable ducts and protected underground routes.

The cable is available in single-core and multicore constructions. N2XY-J versions include a green/yellow protective conductor, while N2XY-O versions do not. XLPE insulation provides reliable thermal performance, and the PVC sheath gives practical protection for general indoor and outdoor fixed installations.

 

Application of N2XY Cable:

N2XY is used for fixed power distribution where a robust XLPE/PVC cable is required. It can be installed on cable trays, in ducts and conduits, inside buildings, in industrial service areas and in protected outdoor routes.

  • Industrial plants, workshops and process facilities.
  • Commercial buildings, warehouses and utility rooms.
  • Low-voltage distribution boards and equipment connections.
  • Infrastructure, water-treatment and energy projects.
  • Cable ducts and protected underground power routes.

Because standard N2XY is unarmoured, exposed routes with impact, crushing or excavation risk may require conduit, covers or an armoured cable. It is intended for fixed installation rather than continuous movement or portable equipment.

 

Technique Data of Our N2XY Cable:

Technical Item N2XY Cable Specification
Cable designation N2XY-J / N2XY-O
Rated voltage 0.6/1 kV
Conductor Copper, solid or stranded according to cable size
Conductor class IEC 60228 Class 1 or Class 2
Insulation XLPE (cross-linked polyethylene)
Outer sheath PVC, commonly black
Core construction Single-core and multicore
Protective conductor Included in N2XY-J; not included in N2XY-O
Maximum conductor temperature Commonly 90°C in normal operation
Installation Fixed indoor, outdoor, duct, tray and protected underground installation
Common standards DIN VDE 0276-603 / HD 603, IEC 60502-1, IEC 60228

 

N2XY vs N2XH and NYY Cable:

N2XY, N2XH and NYY are all fixed power cables, but their insulation and sheath materials suit different project requirements. N2XY combines XLPE insulation with a PVC sheath. N2XH uses a halogen-free sheath system, while NYY normally uses PVC for both insulation and sheath.

Feature N2XY N2XH NYY
Insulation XLPE XLPE PVC
Outer sheath PVC Halogen-free low-smoke compound PVC
Typical use General fixed power distribution Projects requiring LSZH performance General PVC power distribution
Normal conductor temperature Commonly 90°C Commonly 90°C Commonly 70°C
Main selection point XLPE thermal performance with PVC sheath Low smoke and halogen-free requirements Conventional PVC construction

N2XH is normally selected when low-smoke and halogen-free performance is specified. NYY remains a conventional PVC cable option. The project cable schedule and fire requirements determine which construction is appropriate.

 